Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Macromol Rapid Commun ; 43(23): e2200557, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35882631

RESUMO

The seamless integration of electronics with living matter requires advanced materials with programmable biological and engineering properties. Here electrochemical methods to assemble semi-synthetic hydrogels directly on electronically conductive surfaces are explored. Hydrogels consisting of poly (ethylene glycol) (PEG) and heparin building blocks are polymerized by spatially controlling the click reaction between their thiol and maleimide moieties. The gels are grown as conformal coatings or 2D patterns on ITO, gold, and PtIr. This study demonstrates that such coatings significantly influence the electrochemical properties of the metal-electrolyte interface, likely due to space charge effects in the gels. Further a promising route toward engineering and electrically addressable extracellular matrices by printing arrays of gels with binary cell adhesiveness on flexible conductive surfaces is highlighted.


Assuntos
Química Click , Hidrogéis , Hidrogéis/química , Química Click/métodos , Polietilenoglicóis/química , Polimerização , Eletrodos
2.
Nat Commun ; 13(1): 1353, 2022 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-35293384

RESUMO

Hydrogels underpin many applications in tissue engineering, cell encapsulation, drug delivery and bioelectronics. Methods improving control over gelation mechanisms and patterning are still needed. Here we explore a less-known gelation approach relying on sequential electrochemical-chemical-chemical (ECC) reactions. An ionic species and/or molecule in solution is oxidised over a conductive surface at a specific electric potential. The oxidation generates an intermediate species that reacts with a macromolecule, forming a hydrogel at the electrode-electrolyte interface. We introduce potentiostatic control over this process, allowing the selection of gelation reactions and control of hydrogel growth rate. In chitosan and alginate systems, we demonstrate precipitation, covalent and ionic gelation mechanisms. The method can be applied in the polymerisation of hybrid systems consisting of more than one polymer. We demonstrate concomitant deposition of the conductive polymer Poly(3,4-ethylenedioxythiophene) (PEDOT) and alginate. Deposition of the hydrogels occurs in small droplets held between a conductive plate (working electrode, WE), a printing nozzle (counter electrode, CE) and a pseudoreference electrode (reference electrode, RE). We install this setup on a commercial 3D printer to demonstrate patterning of adherent hydrogels on gold and flexible ITO foils. Electro-assisted printing may contribute to the integration of well-defined hydrogels on hybrid electronic-hydrogel devices for bioelectronics applications.


Assuntos
Hidrogéis , Impressão Tridimensional , Condutividade Elétrica , Hidrogéis/química , Polímeros/química , Engenharia Tecidual
3.
Front Bioeng Biotechnol ; 9: 770274, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34805123

RESUMO

Most mental disorders, such as addictive diseases or schizophrenia, are characterized by impaired cognitive function and behavior control originating from disturbances within prefrontal neural networks. Their often chronic reoccurring nature and the lack of efficient therapies necessitate the development of new treatment strategies. Brain-computer interfaces, equipped with multiple sensing and stimulation abilities, offer a new toolbox whose suitability for diagnosis and therapy of mental disorders has not yet been explored. This study, therefore, aimed to develop a biocompatible and multimodal neuroprosthesis to measure and modulate prefrontal neurophysiological features of neuropsychiatric symptoms. We used a 3D-printing technology to rapidly prototype customized bioelectronic implants through robot-controlled deposition of soft silicones and a conductive platinum ink. We implanted the device epidurally above the medial prefrontal cortex of rats and obtained auditory event-related brain potentials in treatment-naïve animals, after alcohol administration and following neuromodulation through implant-driven electrical brain stimulation and cortical delivery of the anti-relapse medication naltrexone. Towards smart neuroprosthetic interfaces, we furthermore developed machine learning algorithms to autonomously classify treatment effects within the neural recordings. The neuroprosthesis successfully captured neural activity patterns reflecting intact stimulus processing and alcohol-induced neural depression. Moreover, implant-driven electrical and pharmacological stimulation enabled successful enhancement of neural activity. A machine learning approach based on stepwise linear discriminant analysis was able to deal with sparsity in the data and distinguished treatments with high accuracy. Our work demonstrates the feasibility of multimodal bioelectronic systems to monitor, modulate and identify healthy and affected brain states with potential use in a personalized and optimized therapy of neuropsychiatric disorders.

4.
Nat Biomed Eng ; 4(10): 1010-1022, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32958898

RESUMO

Neuromuscular interfaces are required to translate bioelectronic technologies for application in clinical medicine. Here, by leveraging the robotically controlled ink-jet deposition of low-viscosity conductive inks, extrusion of insulating silicone pastes and in situ activation of electrode surfaces via cold-air plasma, we show that soft biocompatible materials can be rapidly printed for the on-demand prototyping of customized electrode arrays well adjusted to specific anatomical environments, functions and experimental models. We also show, with the monitoring and activation of neuronal pathways in the brain, spinal cord and neuromuscular system of cats, rats and zebrafish, that the printed bioelectronic interfaces allow for long-term integration and functional stability. This technology might enable personalized bioelectronics for neuroprosthetic applications.


Assuntos
Materiais Biocompatíveis , Monitoração Neuromuscular/métodos , Impressão Tridimensional , Próteses e Implantes , Animais , Gatos , Espectroscopia Dielétrica , Estimulação Elétrica , Desenho de Equipamento , Feminino , Tinta , Masculino , Monitoração Neuromuscular/instrumentação , Ratos Wistar , Nervo Isquiático/fisiologia , Medula Espinal/fisiologia , Bexiga Urinária/fisiologia , Peixe-Zebra
5.
Bioelectron Med ; 6: 4, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32232112

RESUMO

Addictive disorders are a severe health concern. Conventional therapies have just moderate success and the probability of relapse after treatment remains high. Brain stimulation techniques, such as transcranial Direct Current Stimulation (tDCS) and Deep Brain Stimulation (DBS), have been shown to be effective in reducing subjectively rated substance craving. However, there are few objective and measurable parameters that reflect neural mechanisms of addictive disorders and relapse. Key electrophysiological features that characterize substance related changes in neural processing are Event-Related Potentials (ERP). These high temporal resolution measurements of brain activity are able to identify neurocognitive correlates of addictive behaviours. Moreover, ERP have shown utility as biomarkers to predict treatment outcome and relapse probability. A future direction for the treatment of addiction might include neural interfaces able to detect addiction-related neurophysiological parameters and deploy neuromodulation adapted to the identified pathological features in a closed-loop fashion. Such systems may go beyond electrical recording and stimulation to employ sensing and neuromodulation in the pharmacological domain as well as advanced signal analysis and machine learning algorithms. In this review, we describe the state-of-the-art in the treatment of addictive disorders with electrical brain stimulation and its effect on addiction-related neurophysiological markers. We discuss advanced signal processing approaches and multi-modal neural interfaces as building blocks in future bioelectronics systems for treatment of addictive disorders.

6.
Bioelectron Med ; 6: 6, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32232223

RESUMO

[This corrects the article DOI: 10.1186/s42234-020-0040-0.].

7.
Adv Sci (Weinh) ; 6(15): 1802077, 2019 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-31406658

RESUMO

Synthetic conductive biopolymers have gained increasing interest in tissue engineering, as they can provide a chemically defined electroconductive and biomimetic microenvironment for cells. In addition to low cytotoxicity and high biocompatibility, injectability and adhesiveness are important for many biomedical applications but have proven to be very challenging. Recent results show that fascinating material properties can be realized with a bioinspired hybrid network, especially through the synergy between irreversible covalent crosslinking and reversible noncovalent self-assembly. Herein, a polysaccharide-based conductive hydrogel crosslinked through noncovalent and reversible covalent reactions is reported. The hybrid material exhibits rheological properties associated with dynamic networks such as self-healing and stress relaxation. Moreover, through fine-tuning the network dynamics by varying covalent/noncovalent crosslinking content and incorporating electroconductive polymers, the resulting materials exhibit electroconductivity and reliable adhesive strength, at a similar range to that of clinically used fibrin glue. The conductive soft adhesives exhibit high cytocompatibility in 2D/3D cell cultures and can promote myogenic differentiation of myoblast cells. The heparin-containing electroconductive adhesive shows high biocompatibility in immunocompetent mice, both for topical application and as injectable materials. The materials could have utilities in many biomedical applications, especially in the area of cardiovascular diseases and wound dressing.

8.
Small ; 15(27): e1901406, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31025545

RESUMO

Electrically conductive materials that mimic physical and biological properties of tissues are urgently required for seamless brain-machine interfaces. Here, a multinetwork hydrogel combining electrical conductivity of 26 S m-1 , stretchability of 800%, and tissue-like elastic modulus of 15 kPa with mimicry of the extracellular matrix is reported. Engineering this unique set of properties is enabled by a novel in-scaffold polymerization approach. Colloidal hydrogels of the nanoclay Laponite are employed as supports for the assembly of secondary polymer networks. Laponite dramatically increases the conductivity of in-scaffold polymerized poly(ethylene-3,4-diethoxy thiophene) in the absence of other dopants, while preserving excellent stretchability. The scaffold is coated with a layer containing adhesive peptide and polysaccharide dextran sulfate supporting the attachment, proliferation, and neuronal differentiation of human induced pluripotent stem cells directly on the surface of conductive hydrogels. Due to its compatibility with simple extrusion printing, this material promises to enable tissue-mimetic neurostimulating electrodes.


Assuntos
Argila/química , Condutividade Elétrica , Hidrogéis/química , Células-Tronco Pluripotentes Induzidas/citologia , Nanopartículas/química , Resinas Acrílicas/química , Compostos Bicíclicos Heterocíclicos com Pontes/química , Adesão Celular , Humanos , Polimerização , Polímeros/química , Silicatos/química
9.
J Neural Eng ; 15(2): 026024, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29339580

RESUMO

OBJECTIVE: We recently developed soft neural interfaces enabling the delivery of electrical and chemical stimulation to the spinal cord. These stimulations restored locomotion in animal models of paralysis. Soft interfaces can be placed either below or above the dura mater. Theoretically, the subdural location combines many advantages, including increased selectivity of electrical stimulation, lower stimulation thresholds, and targeted chemical stimulation through local drug delivery. However, these advantages have not been documented, nor have their functional impact been studied in silico or in a relevant animal model of neurological disorders using a multimodal neural interface. APPROACH: We characterized the recruitment properties of subdural interfaces using a realistic computational model of the rat spinal cord that included explicit representation of the spinal roots. We then validated and complemented computer simulations with electrophysiological experiments in rats. We additionally performed behavioral experiments in rats that received a lateral spinal cord hemisection and were implanted with a soft interface. MAIN RESULTS: In silico and in vivo experiments showed that the subdural location decreased stimulation thresholds compared to the epidural location while retaining high specificity. This feature reduces power consumption and risks of long-term damage in the tissues, thus increasing the clinical safety profile of this approach. The hemisection induced a transient paralysis of the leg ipsilateral to the injury. During this period, the delivery of electrical stimulation restricted to the injured side combined with local chemical modulation enabled coordinated locomotor movements of the paralyzed leg without affecting the non-impaired leg in all tested rats. Electrode properties remained stable over time, while anatomical examinations revealed excellent bio-integration properties. SIGNIFICANCE: Soft neural interfaces inserted subdurally provide the opportunity to deliver electrical and chemical neuromodulation therapies using a single, bio-compatible and mechanically compliant device that effectively alleviates locomotor deficits after spinal cord injury.


Assuntos
Eletrodos Implantados , Potencial Evocado Motor/fisiologia , Traumatismos da Medula Espinal/terapia , Estimulação da Medula Espinal/métodos , Espaço Subdural/fisiologia , Animais , Feminino , Locomoção/fisiologia , Vértebras Lombares , Ratos , Ratos Endogâmicos Lew , Sacro , Medula Espinal/química , Medula Espinal/fisiologia , Traumatismos da Medula Espinal/fisiopatologia , Espaço Subdural/cirurgia
10.
Nat Med ; 22(2): 138-45, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26779815

RESUMO

Electrical neuromodulation of lumbar segments improves motor control after spinal cord injury in animal models and humans. However, the physiological principles underlying the effect of this intervention remain poorly understood, which has limited the therapeutic approach to continuous stimulation applied to restricted spinal cord locations. Here we developed stimulation protocols that reproduce the natural dynamics of motoneuron activation during locomotion. For this, we computed the spatiotemporal activation pattern of muscle synergies during locomotion in healthy rats. Computer simulations identified optimal electrode locations to target each synergy through the recruitment of proprioceptive feedback circuits. This framework steered the design of spatially selective spinal implants and real-time control software that modulate extensor and flexor synergies with precise temporal resolution. Spatiotemporal neuromodulation therapies improved gait quality, weight-bearing capacity, endurance and skilled locomotion in several rodent models of spinal cord injury. These new concepts are directly translatable to strategies to improve motor control in humans.


Assuntos
Potencial Evocado Motor/fisiologia , Retroalimentação Sensorial/fisiologia , Membro Posterior/fisiopatologia , Locomoção/fisiologia , Neurônios Motores/fisiologia , Músculo Esquelético/fisiopatologia , Traumatismos da Medula Espinal/fisiopatologia , Estimulação da Medula Espinal , Raízes Nervosas Espinhais/fisiopatologia , Animais , Fenômenos Biomecânicos , Simulação por Computador , Feminino , Membro Posterior/inervação , Cinética , Músculo Esquelético/inervação , Ratos , Ratos Endogâmicos Lew , Medula Espinal/fisiologia , Traumatismos da Medula Espinal/patologia , Traumatismos da Medula Espinal/reabilitação , Fatores de Tempo , Microtomografia por Raio-X
11.
Science ; 347(6218): 159-63, 2015 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-25574019

RESUMO

The mechanical mismatch between soft neural tissues and stiff neural implants hinders the long-term performance of implantable neuroprostheses. Here, we designed and fabricated soft neural implants with the shape and elasticity of dura mater, the protective membrane of the brain and spinal cord. The electronic dura mater, which we call e-dura, embeds interconnects, electrodes, and chemotrodes that sustain millions of mechanical stretch cycles, electrical stimulation pulses, and chemical injections. These integrated modalities enable multiple neuroprosthetic applications. The soft implants extracted cortical states in freely behaving animals for brain-machine interface and delivered electrochemical spinal neuromodulation that restored locomotion after paralyzing spinal cord injury.


Assuntos
Sistemas de Liberação de Medicamentos/métodos , Dura-Máter , Estimulação Elétrica/métodos , Eletroquimioterapia/métodos , Eletrodos Implantados , Paralisia/terapia , Próteses e Implantes , Traumatismos da Medula Espinal/terapia , Animais , Materiais Biocompatíveis/uso terapêutico , Interfaces Cérebro-Computador , Elasticidade , Locomoção , Camundongos , Camundongos Endogâmicos , Córtex Motor/fisiopatologia , Imagem Multimodal , Neurônios/fisiologia , Paralisia/etiologia , Paralisia/fisiopatologia , Platina , Silício , Medula Espinal/fisiopatologia , Traumatismos da Medula Espinal/complicações , Traumatismos da Medula Espinal/fisiopatologia
12.
Neurosci Res ; 78: 21-9, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24135130

RESUMO

In this conceptual review, we highlight our strategy for, and progress in the development of corticospinal neuroprostheses for restoring locomotor functions and promoting neural repair after thoracic spinal cord injury in experimental animal models. We specifically focus on recent developments in recording and stimulating neural interfaces, decoding algorithms, extraction of real-time feedback information, and closed-loop control systems. Each of these complex neurotechnologies plays a significant role for the design of corticospinal neuroprostheses. Even more challenging is the coordinated integration of such multifaceted technologies into effective and practical neuroprosthetic systems to improve movement execution, and augment neural plasticity after injury. In this review we address our progress in rodent animal models to explore the viability of a technology-intensive strategy for recovery and repair of the damaged nervous system. The technical, practical, and regulatory hurdles that lie ahead along the path toward clinical applications are enormous - and their resolution is uncertain at this stage. However, it is imperative that the discoveries and technological developments being made across the field of neuroprosthetics do not stay in the lab, but instead reach clinical fruition at the fastest pace possible.


Assuntos
Locomoção/fisiologia , Próteses Neurais , Tratos Piramidais/fisiopatologia , Recuperação de Função Fisiológica/fisiologia , Traumatismos da Medula Espinal/reabilitação , Animais , Encéfalo/fisiologia , Interfaces Cérebro-Computador , Terapia por Estimulação Elétrica/métodos , Humanos , Plasticidade Neuronal , Ratos , Vértebras Torácicas
13.
Sci Transl Med ; 5(210): 210ra155, 2013 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-24197736

RESUMO

A severe complication of spinal cord injury is loss of bladder function (neurogenic bladder), which is characterized by loss of bladder sensation and voluntary control of micturition (urination), and spontaneous hyperreflexive voiding against a closed sphincter (detrusor-sphincter dyssynergia). A sacral anterior root stimulator at low frequency can drive volitional bladder voiding, but surgical rhizotomy of the lumbosacral dorsal roots is needed to prevent spontaneous voiding and dyssynergia. However, rhizotomy is irreversible and eliminates sexual function, and the stimulator gives no information on bladder fullness. We designed a closed-loop neuroprosthetic interface that measures bladder fullness and prevents spontaneous voiding episodes without the need for dorsal rhizotomy in a rat model. To obtain bladder sensory information, we implanted teased dorsal roots (rootlets) within the rat vertebral column into microchannel electrodes, which provided signal amplification and noise suppression. As long as they were attached to the spinal cord, these rootlets survived for up to 3 months and contained axons and blood vessels. Electrophysiological recordings showed that half of the rootlets propagated action potentials, with firing frequency correlated to bladder fullness. When the bladder became full enough to initiate spontaneous voiding, high-frequency/amplitude sensory activity was detected. Voiding was abolished using a high-frequency depolarizing block to the ventral roots. A ventral root stimulator initiated bladder emptying at low frequency and prevented unwanted contraction at high frequency. These data suggest that sensory information from the dorsal root together with a ventral root stimulator could form the basis for a closed-loop bladder neuroprosthetic.


Assuntos
Próteses Neurais , Desenho de Prótese , Traumatismos da Medula Espinal/fisiopatologia , Bexiga Urinária/fisiopatologia , Potenciais de Ação , Animais , Axônios/patologia , Estimulação Elétrica , Feminino , Implantes Experimentais , Microeletrodos , Bainha de Mielina/metabolismo , Bloqueio Nervoso , Tamanho do Órgão , Ratos , Ratos Sprague-Dawley , Raízes Nervosas Espinhais/irrigação sanguínea , Raízes Nervosas Espinhais/fisiopatologia , Raízes Nervosas Espinhais/cirurgia , Micção
14.
Adv Mater ; 25(22): 3117-21, 2013 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-23629920

RESUMO

Thin metal films coated on soft elastomeric foam substrates exhibit enhanced electromechanical performance. The open-cell foam structure conveys highly anisotropic mechanical properties within the top, thin capping elastomer at the surface of the foam. Upon stretching, large strain fields inducing cracks and folds localize above the foam cells, while the surrounding cell ligaments remain almost strain-free, enabling stable electrical conduction in the metallic coating.


Assuntos
Elastômeros/química , Ouro/química , Fenômenos Mecânicos , Poliuretanos/química , Condutividade Elétrica , Modelos Moleculares , Conformação Molecular
15.
Acta Biomater ; 9(6): 6936-42, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23499849

RESUMO

Soft bioengineered surfaces offer a route towards modulating the tissue responses to chronically implanted devices and may enhance their functionality. In this communication we fabricate microtopographically rich and mechanically compliant silicone surfaces for use in soft neural interfaces. We observe the interaction of primary rat microglia and astroglia with arrays of tall and short (4.7 and 0.5µm) vertically oriented polydimethylsiloxane (PDMS) micropillars and a flat PDMS surface in vitro. With the pillar size and spacing that we use (1.3µm diameter and 1.6µm edge to edge), glia are found to engulf and bend tall pillars. The cytoskeleton of cells adhering to the pillar arrays lacks actin stress fibers; instead we observe actin ring formations around individual pillars. Tall, but not short pillar arrays are inhibitory to migration and spreading for both microglia and astrocytes. When compared to a flat PDMS surface and short pillar arrays, tall micropillar arrays cause nearly a 2-fold decrease in proliferation rates for both cell types. The antimitotic properties of tall pillar arrays may be useful for reducing the density of the glial capsule around brain-implanted devices.


Assuntos
Materiais Biocompatíveis/química , Dimetilpolisiloxanos/química , Neuroglia/citologia , Neuroglia/fisiologia , Engenharia Tecidual/métodos , Animais , Adesão Celular , Movimento Celular , Proliferação de Células , Sobrevivência Celular , Células Cultivadas , Teste de Materiais , Ratos , Ratos Sprague-Dawley , Propriedades de Superfície
16.
Lab Chip ; 12(14): 2540-51, 2012 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-22569953

RESUMO

In this paper we present a compliant neural interface designed to record bladder afferent activity. We developed the implant's microfabrication process using multiple layers of silicone rubber and thin metal so that a gold microelectrode array is embedded within four parallel polydimethylsiloxane (PDMS) microchannels (5 mm long, 100 µm wide, 100 µm deep). Electrode impedance at 1 kHz was optimized using a reactive ion etching (RIE) step, which increased the porosity of the electrode surface. The electrodes did not deteriorate after a 3 month immersion in phosphate buffered saline (PBS) at 37 °C. Due to the unique microscopic topography of the metal film on PDMS, the electrodes are extremely compliant and can withstand handling during implantation (twisting and bending) without electrical failure. The device was transplanted acutely to anaesthetized rats, and strands of the dorsal branch of roots L6 and S1 were surgically teased and inserted in three microchannels under saline immersion to allow for simultaneous in vivo recordings in an acute setting. We utilized a tripole electrode configuration to maintain background noise low and improve the signal to noise ratio. The device could distinguish two types of afferent nerve activity related to increasing bladder filling and contraction. To our knowledge, this is the first report of multichannel recordings of bladder afferent activity.


Assuntos
Espectroscopia Dielétrica/métodos , Dimetilpolisiloxanos/química , Raízes Nervosas Espinhais/fisiologia , Bexiga Urinária/fisiologia , Animais , Espectroscopia Dielétrica/instrumentação , Impedância Elétrica , Feminino , Microeletrodos , Porosidade , Ratos , Ratos Sprague-Dawley
17.
J Neural Eng ; 9(2): 026005, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22328617

RESUMO

Neuroprostheses interfaced with transected peripheral nerves are technological routes to control robotic limbs as well as convey sensory feedback to patients suffering from traumatic neural injuries or degenerative diseases. To maximize the wealth of data obtained in recordings, interfacing devices are required to have intrafascicular resolution and provide high signal-to-noise ratio (SNR) recordings. In this paper, we focus on a possible building block of a three-dimensional regenerative implant: a polydimethylsiloxane (PDMS) microchannel electrode capable of highly sensitive recordings in vivo. The PDMS 'micro-cuff' consists of a 3.5 mm long (100 µm × 70 µm cross section) microfluidic channel equipped with five evaporated Ti/Au/Ti electrodes of sub-100 nm thickness. Individual electrodes have average impedance of 640 ± 30 kΩ with a phase angle of -58 ± 1 degrees at 1 kHz and survive demanding mechanical handling such as twisting and bending. In proof-of-principle acute implantation experiments in rats, surgically teased afferent nerve strands from the L5 dorsal root were threaded through the microchannel. Tactile stimulation of the skin was reliably monitored with the three inner electrodes in the device, simultaneously recording signal amplitudes of up to 50 µV under saline immersion. The overall SNR was approximately 4. A small but consistent time lag between the signals arriving at the three electrodes was observed and yields a fibre conduction velocity of 30 m s(-1). The fidelity of the recordings was verified by placing the same nerve strand in oil and recording activity with hook electrodes. Our results show that PDMS microchannel electrodes open a promising technological path to 3D regenerative interfaces.


Assuntos
Eletrofisiologia/instrumentação , Microeletrodos , Neurônios Aferentes/fisiologia , Animais , Dimetilpolisiloxanos , Impedância Elétrica , Eletrodos Implantados , Ouro , Masculino , Próteses Neurais , Nervos Periféricos/fisiologia , Estimulação Física , Desenho de Prótese , Ratos , Ratos Sprague-Dawley , Reprodutibilidade dos Testes , Robótica , Razão Sinal-Ruído , Medula Espinal/fisiologia , Interface Usuário-Computador
18.
Langmuir ; 27(8): 4279-84, 2011 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-21410202

RESUMO

Stretchable electronics (i.e., hybrid inorganic or organic circuits integrated on elastomeric substrates) rely on elastic wiring. We present a technique for fabricating reversibly stretchable metallic films by printing silver-based ink onto microstructured silicone substrates. The wetting and pinning of the ink on the elastomer surface is adjusted and optimized by varying the geometry of micropillar arrays patterned on the silicone substrate. The resulting films exhibit high electrical conductivity (∼11 000 S/cm) and can stretch reversibly to 20% strain over 1000 times without failing electrically. The stretchability of the ≥200 nm thick metallic film relies on engineered strain relief in the printed film on patterned PDMS.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...